Background
Routine surveillance cultures are critical in the care of patients with cystic fibrosis (CF) and are used in clinical decision-making .
常规监测培养对于囊性纤维化(CF)患者的护理至关重要,并用于临床决策。
AI 讲解 快速 深入 整句 标记
Due to the improved health of people with CF (pwCF) and the increased use of telehealth for clinical care , there is a strong interest in providing remote care , including remote respiratory specimen collection .
由于囊性纤维化患者(pwCF)的健康状况改善以及远程医疗在临床护理中的使用增加,因此提供远程护理,包括远程呼吸道样本采集,引起了强烈的兴趣。
research_question
Are self-obtained respiratory samples feasible and acceptable for pwCF and are the results comparable with clinic-obtained samples (COSs)?
自我采集的呼吸样本对于囊性纤维化患者是否可行且可接受,其结果是否与临床采集样本(COSs)相当?
study_design_and_methods
pwCF ≥ 1 year of age were enrolled at 6 CF centers (4 pediatric and 2 adult ).
年龄≥1岁的囊性纤维化患者在6个囊性纤维化中心(4个儿科和2个成人)进行了登记。
Two oropharyngeal samples were obtained (order randomized ): 1 COS per each CF center's practice and 1 self-obtained sample (SOS) after standardized education .
获取了两份口咽样本(顺序随机化):每家囊性纤维化(CF)中心的实践获取1份临床操作样本(COS),以及在标准化教育后获取1份自我采集样本(SOS)
The SOS was randomized to immediate vs delayed processing , for transport mimicry .
SOS被随机分为立即处理组与延迟处理组,以模拟运输过程。
Cohen kappa was used to assess agreement between sample types .
使用Cohen kappa评估样本类型之间的一致性。
Surveys were completed to determine feasibility and acceptability .
完成调查以确定可行性和可接受性。
Results
A total of 164 pwCF were enrolled .
共有164名pwCF患者被纳入研究。
Self-collection was feasible (99% successful SOSs ) and acceptable with 88% rating the collection as very easy or easy and 100% being willing to collect another sample if clinically recommended .
自我采样是可行的(99%的成功率),并且可接受,其中88%的受试者认为采样非常容易或容易,并且100%的受试者愿意在临床推荐的情况下再次收集样本。
The overall agreement between COSs and SOSs for any CF pathogen detection was 78.7% (kappa, 0.583; 95% CI , 0.432-0.734), suggesting moderate agreement .
COSs和SOSs在检测任何CF病原体时的一致性为78.7%(kappa值,0.583;95%置信区间,0.432-0.734),表明中度一致性。
Agreement for methicillin-susceptible Staphylococcus aureus detection was 87.9% (kappa, 0.748; 95% CI , 0.594-0.902), suggesting substantial agreement .
对甲氧西林敏感金黄色葡萄球菌检测的一致性为87.9%(kappa值,0.748;95%置信区间,0.594-0.902),表明有相当大的一致性。
Statistical analyses were not completed for other bacterial organisms due to low detection .
由于检出率低,其他细菌的统计分析尚未完成。
Order of sample collection , time to processing , participant age , or collection by self or parent/guardian did not impact agreement .
样本采集的顺序、处理时间、参与者年龄,或是由自己或父母/监护人采集,并未影响一致性。
interpretation
Our results indicate that self-collection is feasible and acceptable for pwCF .
我们的结果表明,自我采样对于囊性纤维化患者是可行且可接受的。
Agreement between sample types suggest that self-collection may offer an alternate option for microbiology surveillance .
样本类型之间的一致性表明,自我采样可能为微生物学监测提供了一个替代方案。
本文献翻译由 AI 辅助生成,仅供文献精读与英语学习参考。临床决策请以 PubMed / PMC 原文为准。